Contemporary Research 19 ICE-HE Ethernet Head End
Contemporary Research 2-way iC-Net devices will send a response over the network whenever there is
there is a change in status or command from an IR remote or front panel.
Response String Structure
Characters in response strings are expressed in a combination of hex and ASCII characters. For clarity,
the following protocol examples use the following conventions:
ASCII characters or strings are shown enclosed in single quotes
Numbers shown that are not in single quotes are a single decimal byte
Parameters shown in < > brackets are single byte
A series of multiple commands or parameters are set apart by [ ] brackets
Commas separate the bytes, but are not part of the protocol
Double quotes enclose the command string, but are not part of the protocol
Command format
― ‗<‘,<dh>,<dl>,<nrb>,<rb1>, <para1> [<rbN>]"
‗< Starts the response
<dh> The zone or high order byte of the device
<dl> The unit or low order byte of the device (0 for global zone)
<nrb> The number of response bytes to follow
<rb1> The first response byte
<para1> Associated parameters, if any
[<rbN>] Multiple responses may be included